D-128 Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes
MBus
0027
Digout Value.Relay 01
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00581
0028
Digout Value.Relay 02
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00583
0031
Digout Value.Digout 11
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00589
0032
Digout Value.Digout 12
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00591
0033
Digout Value.Digout 13
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00593
0034
Digout Value.Digout 14
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00595
0037
Digout Value.Relay 11
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR
2
00601
0038
Digout Value.Relay 12
Monitor::Inputs and Outputs
Parameters::Inputs And Outputs::IO Values
BOOL FALSE ALWAYS OPERATOR 2
00603
0039
Anin 01 Value
Same as PNO 38
REAL
x.x
-100.0 to 100.0
%
NEVER
OPERATOR
00605
0040
Anin 01 Break
Parameters::Inputs And Outputs::IO Values
BOOL
NEVER
OPERATOR
00607
0041
Anin 02 Value
Same as PNO 38
REAL
x.x
-100.0 to 100.0
%
NEVER
OPERATOR
00609
0042
Anout 01 Value
Same as PNO 38
REAL
0.00
Min to Max
%
ALWAYS
OPERATOR
2
00611
0043
Anout 02 Value
Same as PNO 38
REAL
0.00
Min to Max
%
ALWAYS
OPERATOR
2
00613
0044
Comms Required
Setup::Communications::Option
Parameters::Option Comms::Comms
USINT
(enum)
1
1:NONE
2:BACNET IP
3:BACNET MSTP
4:CANOPEN
6:CONTROLNET
7:DEVICENET
8:ETHERCAT
9:ETHERNET IP
10:MODBUS RTU
11:MODBUS TCP
12:PROFIBUS DPV1
13:PROFINET IO
14:PASSIVE SERIAL
CONFIG TECHNICIAN
00615
0045
Comms Fitted
Monitor::Communications::Option
Parameters::Option Comms::Comms
USINT
(enum)
0:UNKNOWN
1:NONE
2:BACNET IP
3:BACNET MSTP
4:CANOPEN
5:CC LINK
6:CONTROLNET
7:DEVICENET
8:ETHERCAT
9:ETHERNET IP
10:MODBUS RTU
11:MODBUS TCP
12:PROFIBUS DPV1
13:PROFINET IO
14:PASSIVE SERIAL
NEVER OPERATOR 1
00617
0046
Comms State Parameters::Option Comms::Comms
USINT
(enum)
0:SETUP
1:NW INIT
2:WAIT PROCESS
3:IDLE
4:PROCESS ACTIVE
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER ENGINEER
00619
0047
Comms Supervised
Same as PNO 45
BOOL
NEVER
OPERATOR
00621
0048
Comms Trip Enable
Same as PNO 44
BOOL
TRUE
ALWAYS
TECHNICIAN
00623
0049
Comms Module Version
Same as PNO 45
DWORD
NEVER
TECHNICIAN
00625
0050
Comms Module Serial
Same as PNO 45
DWORD
NEVER
TECHNICIAN
00627
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals