EasyManuals Logo

R&S ESR Series User Manual

R&S ESR Series
1126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #348 background imageLoading...
Page #348 background image
Spectrum Measurements
R&S
®
ESR
345User Manual 1175.7068.02 ─ 12
Manual.......................................................................................................... 347
Start.............................................................................................................................347
Stop.............................................................................................................................347
Frequency Offset.........................................................................................................347
Signal Track (span > 0)............................................................................................... 347
Track On/Off (span > 0)................................................................................ 348
Track BW (span > 0).....................................................................................348
Track Threshold (span > 0)...........................................................................348
Select Trace (span > 0).................................................................................348
Center
Opens an edit dialog box to enter the center frequency. The allowed range of values
for the center frequency depends on the frequency span.
span > 0: span
min
/2 ≤ f
center
≤ f
max
– span
min
/2
span = 0: 0 Hz ≤ f
center
≤ f
max
f
max
and span
min
are specified in the data sheet.
Remote command:
[SENSe:]FREQuency:CENTer on page 822
CF Stepsize
Opens a submenu to set the step size of the center frequency.
The step size defines the value by which the center frequency is increased or
decreased when the arrow keys are pressed. When you use the rotary knob the center
frequency changes in steps of 10% of the "Center Frequency Stepsize".
The step size can be set to a fraction of the span (span > 0) or a fraction of the resolu-
tion bandwidth (span = 0) or it can be set to a fixed value manually.
Apart from the =Center, =Marker and Manual softkeys, the other softkeys are dis-
played depending on the selected frequency span.
0.1*Span (span > 0) ← CF Stepsize
Sets the step size for the center frequency to 10 % of the span.
Remote command:
FREQ:CENT:STEP:LINK SPAN, see [SENSe:]FREQuency:CENTer:STEP:LINK
on page 823
FREQ:CENT:STEP:LINK:FACT 10PCT, see [SENSe:]FREQuency:CENTer:STEP:
LINK:FACTor on page 824
0.1*RBW (span > 0) ← CF Stepsize
Sets the step size for the center frequency to 10 % of the resolution bandwidth.
This is the default setting.
Remote command:
FREQ:CENT:STEP:LINK RBW, see [SENSe:]FREQuency:CENTer:STEP:LINK
on page 823
FREQ:CENT:STEP:LINK:FACT 10PCT, see [SENSe:]FREQuency:CENTer:STEP:
LINK:FACTor on page 824
Configuration

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ESR Series and is the answer not in the manual?

R&S ESR Series Specifications

General IconGeneral
BrandR&S
ModelESR Series
CategoryReceiver
LanguageEnglish

Related product manuals