EasyManua.ls Logo

R&S ESR Series

R&S ESR Series
1126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
ESR
824User Manual 1175.7068.02 ─ 12
[SENSe:]FREQuency:CENTer:STEP:LINK:FACTor <Factor>
This command defines a step size factor if the center frequency step size is coupled to
the span or the resolution bandwidth.
Parameters:
<Factor> Range: 1 to 100
*RST: 10
Default unit: PCT
Example:
FREQ:CENT:STEP:LINK:FACT 20PCT
Manual operation: See "0.1*Span (span > 0)" on page 345
See "0.1*RBW (span > 0)" on page 345
See "0.5*Span (span > 0)" on page 346
See "0.5*RBW (span > 0)" on page 346
[SENSe:]FREQuency:MODE <Mode>
This command selects the frequency mode.
between span > 0 and zero span in the "Spectrum" mode.
Parameters:
<Mode> CW
Selects the time domain (span = 0).
In the time domain, define the measurement frequency with
[SENSe:]FREQuency:CENTer.
FIXed
Selects the time domain (span = 0).
In the time domain, define the measurement frequency with
[SENSe:]FREQuency:CENTer.
SWEep
Selects the frequency domain (span > 0).
In the frequency domain, define the frequency characteristics
with the following commands:
[SENSe:]FREQuency:STARt
[SENSe:]FREQuency:STOP
[SENSe:]FREQuency:SPAN
[SENSe:]FREQuency:CENTer
*RST:
SWEep
Example:
FREQ:MODE SWE
Selects the frequency domain.
Usage: SCPI confirmed
[SENSe:]FREQuency:OFFSet <Offset>
This command defines the frequency offset.
Remote Commands in Spectrum Analyzer Mode

Table of Contents