Multi-speed parameter group 04
PARAMETER DESCRIPTION 131
5.5 Multi-speed parameter group 04
Group
Parameter
Number
Name
Setting Range
Default
Page
04-00
P.4
Speed1(high speed)
0~650.00Hz
60.00Hz
133
04-01
P.5
Speed2(mediumspeed)
0~650.00Hz
30.00Hz
133
04-02
P.6
Speed3(low speed)
0~650.00Hz
10.00Hz
133
04-03
P.24
Speed4
0~650.00Hz
99999
133
99999: Function invalid
04-04
P.25
Speed5
Same as 04-03
99999
133
04-05
P.26
Speed6
Same as 04-03
99999
133
04-06
P.27
Speed7
Same as 04-03
99999
133
04-07
P.142
Speed8
Same as 04-03
99999
133
04-08
P.143
Speed9
Same as 04-03
99999
133
04-09
P.144
Speed10
Same as 04-03
99999
133
04-10
P.145
Speed11
Same as 04-03
99999
133
04-11
P.146
Speed12
Same as 04-03
99999
133
04-12
P.147
Speed13
Same as 04-03
99999
133
04-13
P.148
Speed14
Same as 04-03
99999
133
04-14
P.149
Speed15
Same as 04-03
99999
133
04-15
P.100
Programmed operation
minute / second selection
0: Select minute as the time increment.
1
134
1: Select second as the time increment.
04-16
P.121
Run direction in each section
0~255
0
134
04-17
P.122
Programmed operation cycle
selection
0:Off
0
135
1~8: Start cycle from the set section.
04-18
P.123
Programmed operation
acceleration / deceleration
time setting selection
0: Acceleration time is 01-06(P.7), deceleration
time is 01-07(P.8).
0
135
1: Acceleration and deceleration time is set by
04-35(P.111)~04-42(P.118).
04-19
P.131
Programmed operation
mode speed 1
0~650.00Hz
0.00 Hz
135
04-20
P.132
Programmed operation
mode speed 2
0~650.00Hz
0.00 Hz
135
04-21
P.133
Programmed operation
mode speed 3
0~650.00Hz
0.00 Hz
135
04-22
P.134
Programmed operation
mode speed 4
0~650.00Hz
0.00 Hz
135
04-23
P.135
Programmed operation
mode speed 5
0~650.00Hz
0.00 Hz
135
04-24
P.136
Programmed operation
mode speed 6
0~650.00Hz
0.00 Hz
135
04-25
P.137
Programmed operation
mode speed 7
0~650.00Hz
0.00 Hz
135
04-26
P.138
Programmed operation
mode speed 8
0~650.00Hz
0.00 Hz
135

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish

Related product manuals