Basic parameter group 01
PARAMETER DESCRIPTION 77
5.2 Basic parameter group 01
High-speed maximum
frequency
50Hz system setting: 0~650.00Hz
60Hz system setting: 0~650.00Hz
99999: Change according to the input voltage
Acceleration/deceleration
curve selection
0: Linear acceleration /deceleration curve
1: S shape acceleration /deceleration curve 1
2: S shape acceleration /deceleration curve 2
3: S shape acceleration /deceleration curve 3
3.7K and below: 0~360.00s/0~3600.0s
5.5K and above: 0~360.00s/0~3600.0s
3.7K and below: 0~360.00s/0~3600.0s
5.5K~7.5K :0~360.00s/0~3600.0s
11K and above:0~360.00s/0~3600.0s
Acceleration/deceleration
time increments
0: Time increment is 0.01s
1: Time increment is 0.1s
Acceleration/deceleration
reference frequency
50Hz system setting:1.00~650.00Hz
60Hz system setting: 1.00~650.00Hz
0: For constant torque loads (conveyor belt,etc.)
1: For variable torque loads (fans and pumps, etc.)
5~13: Special two-point V/F curve
14: V/F complete detached mode
15: V/F semidetached mode
JOG acceleration/
deceleration time
Output frequency filter time