Appendix 3
APPENDIX 353
7.3 Appendix 3 Warning Code List
Code
Screen Display
Cause
Troubleshooting
Current stall
glittering
When the output current is larger
than Stall prevention operation
level, the three lights on the left
side of the screen flicker, indicating
that the inverter is in current stall
mode. In this case the motor may
not run smoothly.
Check if the values of P.22,
P.23, and P.66 are proper.
Check if the values of P.7 and
P.8 are too small.
If there is rapid acceleration or
deceleration, please extend
the acceleration and
deceleration time.
Avoid sharp increase of load
Check whether there is a short
circuit in the motor terminal U/
t1-v/t2-w /T3.
Voltage stall
glittering
When the voltage between +/P
and -/N is too high, the three lights
on the right side of the screen
flicker, indicating that the inverter
is in voltage stall mode. Then the
motor may not run smoothly.
1Add a brake resistor
between +/P and PR.
2Check if the values of P.7
and P.8 are too small
LV
Low voltage
Input voltage is low.
Supply with the normal voltage

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish

Related product manuals