Speed and torque control parameter group11
PARAMETER DESCRIPTION 239
5.12.6 Second motor control parameter
Realize second motor function by setting second motor control parameter and digital input terminal.
Parameter
Name
Default
Setting Range
Content
11-30
P.371
Second motor speed
control proportional
coefficient 1
100.0
02000.0
---
99999
11-31
P.372
Second motor speed
control integral time 1
0.30s
020.00s
---
99999
11-32
P.373
Second motor PI
coefficient switchover
frequency 1
5.00Hz
011-35 (P.376)Hz
---
99999
11-33
P.374
Second motor speed
control proportional
coefficient 2
100.0
02000.0
---
99999
11-34
P.375
Second motor speed
control integral time 2
0.30s
020.00s
---
99999
11-35
P.376
Second motor PI
coefficient switchover
frequency 2
10.00Hz
11-32(P.373)~650.00
Hz
---
99999
11-36
P.377
Second motor current
control proportional
coefficient
0
020
---
99999
Second motor control parameter
When 00-22(P. 370) 99999 and RT signal is ON, second motor control parameter 11-30(P.371)~11-36(P.377) are
valid. For the second function parameter, please refer to Section 5.2.10.
Please refer to 05-22(P.332)~05-38(P.394) for the second motor parameter.
For the parameter setting, please refer to 11-00(P.320)~11-06(P.326) parameter function.
Setting

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish

Related product manuals