Appendix 1
APPENDIX 277
Parameter
Number
Group
Name
Setting Range
Default
Page
P.18
01-02
High-speed maximum
frequency
01-00(P.1)~650.00Hz
120.00Hz
79
P.19
01-04
Base voltage
0~1000.0V
99999
79
99999: Change according to the input voltage
P.20
01-09
Acceleration/deceleration
reference frequency
50Hz system setting: 1.00~650.00Hz
50.00Hz
80
60Hz system setting: 1.00~650.00Hz
60.00Hz
P.21
01-08
Acceleration/deceleration
time increments
0: Time increment is 0.01s
0
80
1: Time increment is 0.1s
P.22
06-01
Stall prevention operation
level
0~400.0%
150.0%
151
P.23
06-02
Stall prevention operation
level correction factor
0~150.0%
99999
151
99999: Stall prevention operation level is the
setting value of 06-01(P.22).
P.24
04-03
Speed 4
0~650.00Hz
99999
133
99999: Off
P.25
04-04
Speed 5
Same as 04-03
99999
133
P.26
04-05
Speed 6
Same as 04-03
99999
133
P.27
04-06
Speed 7
Same as 04-03
99999
133
P.28
01-15
Output frequency filter
time
0~1000ms
0ms
86
P.29
01-05
Acceleration/deceleration
curve selection
0: Linear acceleration /deceleration curve
0
80
1: S shape acceleration /deceleration curve 1
2: S shape acceleration /deceleration curve 2
3: S shape acceleration /deceleration curve 3
P.30
06-05
Regenerative brake
function selection
0: Brake duty is fixed at 3%, parameter 06-06
(P.70) will be off.
0
153
1: Brake duty is 06-06(P.70) value.
P.31
00-12
Soft-PWM carrier
operation selection
0: Off
0
69
1: When 00-11(P.72)< 5, Soft-PWM is on (only
apply to V/F control )
P.32
07-02
COM1 Serial
communication baud rate
0: Baud rate: 4800bps
1
168
1: Baud rate: 9600bps
2: Baud rate: 19200bps
3: Baud rate: 38400bps
4: Baud rate: 57600bps
5: Baud rate: 115200bps
P.33
07-00
COM1 Communication
protocol selection
0: Modbus protocol
1
168
1: Shihlin protocol
2:PLC protocol (Effective when using Shilin
built-in PLC)
P.34
07-11
Communication
EEPROM write-in
selection
0: When writing parameters in communication
mode, write in RAM and EEPROM
0
184
1: When writing parameters through
communication, only write into RAM

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish

Related product manuals