EasyManuals Logo

Shihlin electric SE3 Series User Manual

Shihlin electric SE3 Series
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
Multi-speed parameter group04
PARAMETER DESCRIPTION 136
Parameter
Name
Default
Setting Range
Content
04-34
P.108
Programmed operation mode
speed 8 operating time
0.0s
06000.0s
---
04-35
P.111
Programmed operation mode
speed 1 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-36
P.112
Programmed operation mode
speed 2 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-37
P.113
Programmed operation mode
speed 3 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-38
P.114
Programmed operation mode
speed 4 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-39
P.115
Programmed operation mode
speed 5 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-40
P.116
Programmed operation mode
speed 6 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-41
P.117
Programmed operation mode
speed 7Acc/Dec time
0.00s
0600.00s/
06000.0s
---
04-42
P.118
Programmed operation mode
speed 8 Acc/Dec time
0.00s
0600.00s/
06000.0s
---
Programmed operation mode
Programmed operation mode
1. The calculation method of running time and acceleration/deceleration time for each speed is shown in the
following figure:
frequency
Run
forward
Run
reverse
04-35
(P.111)
04-36
(P.112)
04-37
(P.113)
04-38
(P.114)
pause
04-39
(P.115)
04-40
(P.116)
04-41
(P.117)
04-42
(P.118)
04-42
(P.118)
04-27
(P.101)
04-28
(P.102)
04-29
(P.103)
04-30
(P.104)
04-31
(P.105)
04-32
(P.106)
04-33
(P.107)
04-34
(P.108)
2. Setting method of operation direction: set in binary (8 bit), then convert into decimal and set in parameter
04-16. Wherein, 1 means forward rotation, 0 means reverse rotation, the highest bit is the direction of speed 8,
and the lowest bit is the direction of speed 1.
For example: if speed 1 is forward, speed 2 is reverse, speed 3 is reverse, speed 4 is forward, speed 5 is
reverse, speed 6 is forward, speed 7 is forward, and speed 8 is reverse, then the binary number is 01101001.
04-16(P.121)0×2
7
+1×2
6
+1×2
5
+0×2
4
+1×2
3
+0×2
2
+0×2
1
+1×2
0
105
3. When 04-16(P.121) is set to 0, there will be no cycle operation.
4. When 04-17(P.122) is 1~8, it is the section that will cycle to after the first cycle.
Setting

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish

Related product manuals