01/02
6-19
8825/8830 Printer
Wavy Lines When Connected To XPC , LL-52 Errors
General Procedures
Wavy Lines When Connected To XPC or Non Xerox
Controller
PROBLEM
The printer produces prints with wavy lines when connected to a Xerox XPC or a non Xerox
controller. This problem does not occur with a Xerox controller due to the short interface
cable.
CAUSE
There is a timing problem in the P193R interface.
SOLUTION
Order and install a TAG 10 IOT Control PWB. This part is on “j” control you must call tech
support to get approval before placing an order.
REQUIREMENTS FOR FIELD RESOLUTION
• DOCUMENTATION
N/A
• TAG 10
• PART NUMBERS
600K62420 TAG 10 UPGRADE KIT
• CUT IN SERIAL NUMBER
US - 8YG060517
EO - 110907207-5
LL-52 Errors After Installing New Control PWB
PROBLEM
LL-52 errors after installing a new control pwb.
CAUSE
NVM eprom was not moved from the original Control PWB to the new Control PWB.
SOLUTION
Ensure that when the Control PWB is changed, that the NVM eprom (Component U40) is
transferred to the new PWB. Ensure that the NVM eprom is installed onto the Control PWB
with the “dot” in the lower left corner.
REQUIREMENTS FOR FIELD RESOLUTION
• DOCUMENTATION
• REP 3.1
• TAG N/A
PART NUMBERS
N/A
• CUT IN SERIAL NUMBER