EasyManua.ls Logo

YASKAWA GA700 - Page 335

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
6
6.3 List of Fault, Minor Fault, Alarm, and Error Codes
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 335
Display (Hex.) Name ALM LED Type Ref.
oPE03 Multi-Function Input Setting Err Flashing Parameter Setting Errors 374
oPE05 Run Cmd/Freq Ref Source Sel Err Flashing Parameter Setting Errors 376
oPE06 Control Method Selection Error Flashing Parameter Setting Errors 377
oPE07 Analog Input Selection Error Flashing Parameter Setting Errors 377
oPE08 Parameter Selection Error Flashing Parameter Setting Errors 377
oPE09 PID Control Selection Fault Flashing Parameter Setting Errors 378
oPE10 V/f Data Setting Error Flashing Parameter Setting Errors 378
oPE11 Carrier Frequency Setting Error Flashing Parameter Setting Errors 379
oPE13 Pulse Monitor Selection Error Flashing Parameter Setting Errors 379
oPE15 Torque Control Setting Error Flashing Parameter Setting Errors 379
oPE16 Energy Saving Constants Error Flashing Parameter Setting Errors 379
oPE18 Online Tuning Param Setting Err Flashing Parameter Setting Errors 379
oPE20 PG-F3 Setting Error Flashing Parameter Setting Errors 380
oPE33 Digital Output Selection Error Flashing Parameter Setting Errors 380
oPr (001E) Keypad Connection Fault Illuminated Fault 354
oS (0010) Overspeed Flashing Alarm 370
oS (0018) Overspeed Illuminated Fault 354
ov (0002) DC Bus Overvoltage Flashing Alarm 370
ov (0008) Overvoltage Illuminated Fault 355
PASS Modbus Communication Test Flashing Not an alarm. 371
PF (0047) Input Phase Loss Flashing Alarm 371
PF (001B) Input Phase Loss Illuminated Fault 356
PGo (0012) Encoder (PG) Feedback Loss Flashing Alarm 371
PGo (001A) Encoder (PG) Feedback Loss Illuminated Fault 356
PGoH (002B) Encoder (PG) Hardware Fault Flashing Alarm 371
PGoH (0038) Encoder (PG) Hardware Fault Illuminated Fault 356
rdEr Error Reading Data - Copy Function Error 387
rF (004E) Braking Resistor Fault Illuminated Fault 357
rH (0010) Braking Resistor Overheat Illuminated Fault 357
rr (000F) Dynamic Braking Transistor Fault Illuminated Fault 357
rUn (001B) Motor Switch during Run Flashing Alarm 371
SC (0005) Short Circuit/IGBT Failure Illuminated Fault 357
SCF (040F) Safety Circuit Fault Illuminated Fault 358
SE (0020) Modbus Test Mode Error Flashing Alarm 371
SEr (003B) Speed Search Retries Exceeded Illuminated Fault 358
STo (003C) Safe Torque OFF Flashing Alarm 372
SToF (003B) Safe Torque OFF Hardware Flashing Alarm 372
STPo (0037) Motor Step-Out Detected Illuminated Fault 358
SvE (0026) Zero Servo Fault Illuminated Fault 358
TiM (0089) Keypad Time Not Set Flashing Alarm 372
TiM (0401) Keypad Time Not Set Illuminated Fault 359
TrPC (0042) IGBT Maintenance Time (90%) Flashing Alarm 372
UL3 (001E) Undertorque Detection 1 Flashing Alarm 372