6.7 Auto-Tuning Errors
382 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Code Name Causes Possible Solutions
End7 No-Load Current Alarm The Auto-Tuning results of the motor
no-load current value were not in the
applicable range.
Examine and repair damaged motor wiring.
Auto-Tuning results were less than 5%
of the motor rated current.
Make sure that the input motor nameplate data is
correct, and do Auto-Tuning again.
Code Name Causes Possible Solutions
Er-01 Motor Data Error The motor nameplate data entered
during Auto-Tuning is incorrect.
Make sure that the input motor nameplate data is
correct.
Do Auto-Tuning again and correctly set the
motor nameplate data.
The combination of the motor rated
power and motor rated current do not
match.
Examine the combination of drive capacity and
motor output.
Do Auto-Tuning again, and correctly set the
motor rated power and motor rated current.
The combination of the motor rated
current that was entered during Auto-
Tuning and E2-03 [Motor No-Load
Current] do not match.
1. Examine the motor rated current and the no-
load current.
2. Set E2-03 correctly.
3. Do Auto-Tuning again, and correctly set the
motor rated current.
The combination of the setting values of
Motor Base Frequency and Motor Base
Speed do not match.
Do Auto-Tuning again, and correctly set the Motor
Base Frequency and Motor Base Speed.
Code Name Causes Possible Solutions
Er-02 Drive in an Alarm State The motor nameplate data entered
during Auto-Tuning is incorrect.
Make sure that the input motor nameplate data is
correct.
Do Auto-Tuning again and correctly set the
motor nameplate data.
There is a defective motor cable or cable
connection.
Examine and repair motor wiring.
The load is too heavy. Decrease the load.
Examine the machine area to see if, for example,
the motor shaft is locked.
The drive detected a minor fault during
Auto-Tuning.
1. Stop Auto-Tuning.
2. Examine the minor fault code and remove the
cause of the problem.
3. Do Auto-Tuning again.
Code Name Causes Possible Solutions
Er-03 STOP Button was Pressed
During Auto-Tuning, was
pushed and Auto-Tuning was
interrupted.
Auto-Tuning did not complete correctly. Do Auto-
Tuning again.
Code Name Causes Possible Solutions
Er-04 Line-to-Line Resistance
Error
The Auto-Tuning results were not in the
applicable parameter setting range.
Auto-Tuning did not complete in a pre-
set length of time.
There is a defective motor cable or cable
connection.
Examine and repair motor wiring.
Disconnect the machine from the motor and do
Rotational Auto-Tuning again.
The motor nameplate data entered
during Auto-Tuning is incorrect.
Make sure that the input motor nameplate data is
correct.
Do Auto-Tuning again and correctly set the
motor nameplate data.