10.20 Parameters Changed by E1-03 [V/f Pattern Selection]
622 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
*2 The default setting varies depending on the setting of E5-01 [Motor Code Selection].
*3 This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 10.3 Parameters Changed by E1-03 (2257 to 2415 and 4140 to 4675)
No.
Uni
t
Setting
Control Method (Value
set in A1-02)
E1-
03
0 1 2 3 4 5 6 7 8 9 A B C D E F
OL
V
(2)
CLV
(3)
OL
V/
PM
(5)
AO
LV/
PM
(6)
CL
V/
PM
(7)
E1-
04
Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0
120.
0
180.
0
50.0
*1
50.0 50.0
*2 *2 *2
E1-
05
*3
V
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
*1
200.
0
200.
0
*2 *2 *2
E1-
06
Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0
50.0
*1
50.0 50.0
*2 *2 *2
E1-
07
Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0
2.5
*1
3.0 0.0 - - -
E1-
08
*3
V 12.0 12.0 12.0 12.0 35.0 50.0 35.0 50.0 15.0 20.0 15.0 20.0 12.0 12.0 12.0
12.0
*1
13.2 0.0 - - -
E1-
09
Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5
1.3
*1
0.5 0.0
*2 *2
0.0
E1-
10
*3
V 6.0 6.0 6.0 6.0 5.0 6.0 5.0 6.0 7.0 9.0 7.0 11.0 6.0 6.0 6.0
6.0
*1
2.4 0.0 - - -
*1 These values are the default settings for E1-04 through E1-10 and E3-04 through E3-10 [V/f Pattern for Motor 2]. These settings are
the same as those for the V/f pattern when E1-03 = 1 [Constant Trq_60Hz base_60Hz max].
*2 The default setting varies depending on the setting of E5-01 [Motor Code Selection].
*3 This is the value for 200 V class drives. Double the value for 400 V class drives.