EasyManua.ls Logo

YASKAWA GA700 - Page 622

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.20 Parameters Changed by E1-03 [V/f Pattern Selection]
622 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
*2 The default setting varies depending on the setting of E5-01 [Motor Code Selection].
*3 This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 10.3 Parameters Changed by E1-03 (2257 to 2415 and 4140 to 4675)
No.
Uni
t
Setting
Control Method (Value
set in A1-02)
E1-
03
0 1 2 3 4 5 6 7 8 9 A B C D E F
OL
V
(2)
CLV
(3)
OL
V/
PM
(5)
AO
LV/
PM
(6)
CL
V/
PM
(7)
E1-
04
Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0
120.
0
180.
0
50.0
*1
50.0 50.0
*2 *2 *2
E1-
05
*3
V
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
*1
200.
0
200.
0
*2 *2 *2
E1-
06
Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0
50.0
*1
50.0 50.0
*2 *2 *2
E1-
07
Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0
2.5
*1
3.0 0.0 - - -
E1-
08
*3
V 12.0 12.0 12.0 12.0 35.0 50.0 35.0 50.0 15.0 20.0 15.0 20.0 12.0 12.0 12.0
12.0
*1
13.2 0.0 - - -
E1-
09
Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5
1.3
*1
0.5 0.0
*2 *2
0.0
E1-
10
*3
V 6.0 6.0 6.0 6.0 5.0 6.0 5.0 6.0 7.0 9.0 7.0 11.0 6.0 6.0 6.0
6.0
*1
2.4 0.0 - - -
*1 These values are the default settings for E1-04 through E1-10 and E3-04 through E3-10 [V/f Pattern for Motor 2]. These settings are
the same as those for the V/f pattern when E1-03 = 1 [Constant Trq_60Hz base_60Hz max].
*2 The default setting varies depending on the setting of E5-01 [Motor Code Selection].
*3 This is the value for 200 V class drives. Double the value for 400 V class drives.

Table of Contents

Other manuals for YASKAWA GA700

Related product manuals