11.3 b: Application
748 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
b9-02: Zero Servo Completion Window
No.
(Hex.)
Name Description
Default
(Range)
b9-02
(01DB)
Zero Servo
Completion Window
Sets the range to trigger an output terminal set for Zero Servo Complete
during Zero Servo operation. Be sure to set the deviation from the Zero
Servo start position.
10
(0 - 16383)
When the position of the motor shaft is in the range of Zero Servo start position ± b9-02, the drive will activate a
MFDO set for Zero Servo Complete [H2-xx = 33].
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV