Parameter Details
11
11.8 H: Terminal Functions
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 865
■ H1-23: Terminal S3 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-23
(0B72)
Terminal S3 Function
Select 2
Sets the second function for MFDI terminal S3.
F
(1 - 19F)
When MFDI terminal S3 activates, it will operate the function set to H1-03 [Terminal S3 Function Selection] and
the function set to H1-23 at the same time.
When the setting value is F, the function is disabled.
■ H1-24: Terminal S4 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-24
(0B73)
Terminal S4 Function
Select 2
Sets the second function for MFDI terminal S4.
F
(1 - 19F)
When MFDI terminal S4 activates, it will operate the function set to H1-04 [Terminal S4 Function Selection] and
the function set to H1-24 at the same time.
When the setting value is F, the function is disabled.
■ H1-25: Terminal S5 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-25
(0B74)
Terminal S5 Function
Select 2
Sets the second function for MFDI terminal S5.
F
(1 - 19F)
When MFDI terminal S5 activates, it will operate the function set to H1-05 [Terminal S5 Function Selection] and
the function set to H1-25 at the same time.
When the setting value is F, the function is disabled.
■ H1-26: Terminal S6 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-26
(0B75)
Terminal S6 Function
Select 2
Sets the second function for MFDI terminal S6.
F
(1 - 19F)
When MFDI terminal S6 activates, it will operate the function set to H1-06 [Terminal S6 Function Selection] and
the function set to H1-26 at the same time.
When the setting value is F, the function is disabled.
■ H1-27: Terminal S7 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-27
(0B76)
Terminal S7 Function
Select 2
Sets the second function for MFDI terminal S7.
F
(1 - 19F)
When MFDI terminal S7 activates, it will operate the function set to H1-07 [Terminal S7 Function Selection] and
the function set to H1-27 at the same time.
When the setting value is F, the function is disabled.
■ H1-28: Terminal S8 Function Select 2
No.
(Hex.)
Name Description
Default
(Range)
H1-28
(0B77)
Terminal S8 Function
Select 2
Sets the second function for MFDI terminal S8.
F
(1 - 19F)