3. Troubleshooting
3.8 8000 8001: Shutter related errors
Error 8000 : “Opening shutter failed”
This is a warning.
Situation Solution
Disconnected wire unit of the
shutter motor
Reconnect the wire unit (ref SH image 3-23 and image 3-20) of the shutter motor with
the Formatter Interface Board (FIB)
Obstructed shutter plate. Check if nothing is obstructing the shutter plate.
Twisted shutter plate.
Replace the shutter assembly. See "Shutter replacement", page 203.
Malfunction motor of the shutter
assembly.
Replace the shutter assembly. See "Shutter replacement", page 203.
SH
Image 3-23
Error 8001 : “Closing shutter failed”
This is a warning.
Situation Solution
Disconnected wire unit of the
shutter motor
Reconnect the wire unit (ref SH image 3-23 and image 3-20) of the shutter motor with
the Formatter Interface Board (FIB)
Obstructed shutter plate. Check if nothing is obstructing the shutter plate.
Twisted shutter plate.
Replace the shutter assembly. See "Shutter replacement", page 203.
Malfunction motor of the shutter
assembly.
Replace the shutter assembly. See "Shutter replacement", page 203.
Defect end of range switch. Replace the defect switch.
R59770072 FLM SERIES 19/03/2007 55