18. Cooling pump
18.3.2 Mounting the new pump
Necessary tools
•Allenkey3mm
Universal plier
How to mount the pump
1. Place the pump on its seating (A,1)
4
2
3
5
6
7
1
1
A
B
C
Image 18-11
Pump mounting
2. Secure by turning both bolts.
3. Mounting the hose coming from the light processor. First, slide a clip over the hose end (B2).
4. Push the hose end as far as possible on the output nipple of the pump (B3).