Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
289
of 820
4
147.15 Torque init stress 0
Torque init stress of the slave drive at torque coupling at standstill (at slave functionality
only, i.e.
Z147.1– Bit 1…0 = 10, see ZFig. 112– on page 281). If parameter Z147.1–
Bit 12 is set, this additional torque takes effect correspondingly (see ZFig. 114– on page
283).
147.16 Torque init stress 1
Torque init stress of the slave drive at torque coupling at speed limit torque init stress
Z147.17– (at slave functionality only, i.e. Z147.1– Bit 1…0 = 10, see ZFig. 112– on page
281). If parameter Z147.1– Bit 12 is set, this additional torque takes effect correspond-
ingly (see ZFig. 114– on page 283).
147.17 Speed limit torque init stress 1
Speed limit for the torque init stress 1 Z147.16– at torque coupling (at slave functionality
only, i.e. Z147.1– Bit 1…0 = 10, see ZFig. 112– on page 281). If parameter Z147.1–
Bit 12 is set, this additional torque takes effect correspondingly (see ZFig. 114– on page
283). The limit effects bipolar, thus means in both directions of revolution.
147.18 Torque init stress PT
1
time constant
Time constant of PT
1
element to connect the torque init stress to the slave at torque cou-
pling (at slave functionality only, i.e. Z147.1– Bit 1…0 = 10, see ZFig. 112– on page
281).
147.19 Torque set value master
Display of the torque set value of the master at torque coupling in the dimensions for
transmission via fieldbus.
NOTE!
The parameterized torque init stress is set only at the time when both the speed cou-
pling factor master and slave (Z147.5–, Z147.6–) are 1.
NOTE!
The parameterized torque init stress is set only at the time when both the speed cou-