EasyManua.ls Logo

BONFIGLIOLI Agile

BONFIGLIOLI Agile
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Starting behaviour (V/f)
(Factory setting)
if
P30: 110 - IM: sensor-less control (SLC), V/f characteristic
The motor is magnetized (flux-formation, P781) and, if selected, a starting current
(P623) is impressed. The IxR compensation compensates the voltage drop at the stator
resistor.
P620
Operation Mode
0
Off
Control according to V/f characteristic.
1
Magnetization
Set P780 and P781.
2
Magnetization +Current Impression
Set P623, P624, P780 and P781.
3
Magnetization + IxR-Compensation
Set P624, P780 and P781.
4
Magnetization + Current Impression +
IxR-Compensation
Set P623, P624, P780 and P781.
12
Magnetization +Current Impression
with Ramp Stop
Set P623, P624, P780 and P781.
For high start torque.
14
Magnetization + Current Impression
with Ramp Stop + IxR-Compensation
Set P623, P624, P780 and P781.
For high start torque.
P623
Starting Current (value: I
FIN
)
1
PI controller for start current
P621
P part (2.00)
For sufficient torque if a high start torque is re-
quired. The start current is impressed until the
output frequency reaches the value of P624.
P622
I part (50 ms)
P624
Frequency Limit (2.60 Hz)
The starting current is impressed up to this output frequency.
P780
Max. Flux-Formation Time (300 ms)
The current during flux-formation (value of P781) is not impressed longer than this
time.
P781
Current during Flux-Formation (value: I
FIN
)
Upon startup, this current value is impressed. The time for current impression is limited
by P780.
1
Nominal value of frequency inverter
88
Operating Instructions
Agile
06/2013 After first commissioning

Table of Contents