244 100-412-234 REV. 06
237
- S Trg > -
S Abs
The minus suspect trigger
limit value is equal to or
greater than the minus
suspect absolute distance
limit.
Change the - suspect trigger
limit and/or the - suspect
absolute distance limit through
the Alarm Information screen
or Setup menu.
238
+S Trg >
+S Abs
The plus suspect trigger
limit is equal to or greater
than the plus suspect
absolute limit.
Change the +suspect trigger
limit and/or the +suspect
absolute limit through the
Alarm Information screen or
Setup menu.
239
- R Trg > -
R Abs
The minus reject trigger
limit is equal to or greater
than the minus reject
absolute limit.
Change the - reject trigger limit
and/or the - reject absolute
limit through the Alarm
Information screen or Setup
menu.
244
Time S/R
Limit Cross
The plus reject time limit is
equal to or less than the
minus suspect time limit.
Change the +reject time limit
or - suspect time limit through
the Alarm Information screen
or Setup menu.
245
Time S/R
Limit Cross
The plus suspect time is
equal to or less than the
minus reject time limit.
Change the +suspect time limit
or - reject time limit through
the Alarm Information screen
or Setup menu.
246
Time S/R
Limit Cross
The plus reject time limit is
equal to or less than the
plus suspect time limit.
Change the +reject time limit
or +suspect time limit through
the Alarm Information screen
or Setup menu.
247
Time S/R
Limit Cross
The minus reject time limit
is equal to or greater than
the minus suspect time
limit.
Change the - reject time limit
or - suspect time limit through
the Alarm Information screen
or Setup menu.
248
Eng S/R
Limit Cross
The plus reject energy limit
is equal to or less than the
minus suspect energy limit.
Change the +reject energy
limit or - suspect energy limit
through the Alarm Information
screen or Setup menu.
249
Eng S/R
Limit Cross
The plus suspect energy
limit is equal to or less than
the minus reject energy
limit.
Change the +suspect energy
limit or - reject energy limit
through the Alarm Information
screen or Setup menu.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action