F S/R Limit
Cross
The plus suspect force limit
is equal to or less than the
minus reject force limit.
Change the +suspect force
limit and/or the - reject force
limit through the Alarm
Information screen or Setup
menu.
260
Trg S/R
Limit Cross
The plus reject trigger
distance limit is equal to or
less than the minus suspect
trigger distance limit.
Change the +reject trigger
limit or - suspect trigger limit
through the Alarm Information
screen or Setup menu.
261
Trg S/R
Limit Cross
The plus suspect
trigger distance limit is
equal or less than the minus
reject trigger distance limit.
Change the +suspect trigger
limit or - reject trigger limit
through the Alarm Information
screen or Setup menu.
262
Trg S/R
Limit Cross
The plus reject trigger
distance limit is equal to or
less than the plus suspect
trigger distance limit.
Change the +reject trigger
limit or +suspect trigger limit
through the Alarm Information
screen or Setup menu.
263
Trg S/R
Limit Cross
The minus reject trigger
distance limit is equal to or
greater than the minus
suspect trigger distance
limit.
Change the - reject trigger limit
or - suspect trigger limit
through the Alarm Information
screen or Setup menu.
269
Energy
Comp
Crossed
The energy minimum and
maximum settings are
crossed. This alarm is only
valid when energy
compensation is on.
Change the minimum and
maximum energy
compensation limits through
the Alarm Information screen
or Setup menu.
270
Pretrigger
Conflict
The pretrigger
distance is equal to or
greater than the plus
suspect absolute limit.
Change the pretrigger distance
or +suspect trigger limit
through the Alarm Information
screen or Setup menu.
271
Pretrigger
Conflict
The pretrigger
distance is equal to or
greater than the plus reject
trigger limit.
Change the pretrigger distance
or +reject trigger limit through
the Alarm Information screen
or Setup menu.
272
Pretrigger
Conflict
The pretrigger
distance is equal to or
greater than the plus
suspect trigger limit.
Change the pretrigger distance
or +suspect trigger limit
through the Alarm Information
screen or Setup menu.
273
Pretrigger
Conflict
The pretrigger
distance is equal to or
greater than the minus
reject trigger limit.
Change the pretrigger distance
or - reject trigger limit through
the Alarm Information screen
or Setup menu.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action