100-412-234 REV. 06 249
292
Energy
Comp
Conflict
The plus suspect energy
limit is equal to or less than
the
minimum energy
compensation value. This
alarm occurs in time mode
only.
Change the +Suspect energy
limit or minimum energy
compensation through the
Alarm Information screen or
Setup menu.
298
Rapid Trav.
Conflict
The rapid traverse distance
is equal to or greater than
the minus reject absolute
limit.
Either increase the reject
distance limit or decrease the
rapid traverse distance.
633
Sys. Pres.
Incorrect
The system pressure is out
of tolerance (+/-3 PSI). The
pressure is read only after
five seconds of idle time
while in ready. This alarm
does not remove the ready
signal because that would
prevent entry into horn
down. Horn down is the
only place where the
pressure can be viewed.
20A
+- Eng Limit
Crossed
The reject limits for energy
that you have entered are
reversed.
Change the reject energy limits
through the Alarm Information
screen or Setup menu.
20B
+ - Pwr
Limit
Crossed
The suspect limits for power
that you have entered are
reversed.
Change the suspect power
limits through the Alarm
Information screen or Setup
menu.
20C
+ - Pwr
Limit
Crossed
The reject limits for power
that you have entered are
reversed.
Change the reject power limits
through the Alarm Information
screen or Setup menu.
20E
+ - Rej Limit
Crossed
The + reject freq limit and -
reject freq limit values are
crossed.
Either make the correction or
run a horn scan to
automatically correct. This
alarm is valid for VGA only.
20F
+ - Abs
Limit
Crossed
The reject limits for
absolute distance that you
have entered are reversed.
Change the reject absolute
distance limits through the
Alarm Information screen or
Setup menu.
22A
Amp Step
Conflict
The amplitude step at
collapse value is equal to or
greater than collapse cutoff.
Change the amplitude step or
collapse cutoff through the
Alarm Information screen or
Setup menu.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action

Table of Contents