254 100-412-234 REV. 06
2A2
Rapid Trav.
Conflict
The rapid traverse distance
is equal to or greater than
the minus suspect trigger
limit.
Either increase the suspect
distance limit or decrease the
rapid traverse distance.
2A3
Rapid Trav.
Conflict
The rapid traverse distance
is equal to or greater than
the absolute distance cutoff.
This alarm can occur in all
weld modes except
absolute.
Either increase the absolute
cutoff distance or decrease the
rapid traverse distance.
2A4
Rapid Trav.
Conflict
The rapid traverse distance
is equal to or greater than
the absolute distance. This
alarm can occur only in the
absolute welding mode.
Either increase the absolute
cutoff distance or decrease the
rapid traverse distance.
2A6
Hold
Pressure
Conflict
Hold pressure less than
weld pressure.
Change the hold pressure to be
greater than or equal to the
weld pressure.
2D6
Trg Force
Conflict
The trigger force is equal to
or greater than the plus
suspect weld force limit
Change the trigger force and/or
the +suspect weld force limit
through the Alarm Information
screen or Setup menu.
2D7
Trg Force
Conflict
The trigger force is equal to
or greater than the plus
reject weld force limit.
Change the trigger force and/or
the +reject weld force limit
through the Alarm Information
screen or Setup menu.
2DC
Energy
Comp
Conflict
The minus reject energy
limit is equal to or less than
the minimum energy
compensation value.
Change the - Reject energy
limit or minimum energy
compensation through the
Alarm Information screen or
Setup menu.
2DD
Energy
Comp
Conflict
The minus suspect energy
limit is equal to or less than
the maximum energy
compensation value. This
alarm occurs in time mode
only.
Change the - Suspect energy
limit or maximum energy
compensation through the
Alarm Information screen or
Setup menu.
2DE
Energy
Comp
Conflict
The plus energy reject limit
is equal to or greater than
the energy compensation
maximum value
Change the +Reject energy
limit or maximum energy
compensation through the
Alarm Information screen or
Setup menu.
Table B.5 Setup Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action