EasyManuals Logo

Campbell CR800 Series User Manual

Campbell CR800 Series
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #255 background imageLoading...
Page #255 background image
Section 7. Installation
255
SlowSequence
Do
SDI12SensorSetup(10,1,0,1)
Delay(1,500,mSec)
SDI12SensorResponse(SDI_Source)
Loop
EndSequence
EndProg
SDI-12 Sensor Configuration CRBasic Example Results
Measurement
Command from
SDI-12 Recorder
Source Variables
Accessed from the
CR800 acting as a
SDI-12 Sensor
Contents of
Source Variables
0M!
Source(1), Source(2)
Temperature °C, battery
voltage
0M0!
Same as 0M!
0M1!
Source(3), Source(4)
Temperature °F, battery
voltage
0M2!
Source(5), Source(6)
Temperature °C, battery
mV
0M3!
Source(7), Source(8)
Temperature °F, battery
mV
0M4!
Source(9), Source(10)
Serial number, lithium
battery voltage
7.7.14.4 SDI-12 Power Considerations
When a command is sent by the CR800 to an SDI-12 probe, all probes on the
same SDI-12 port will wake up. However, only the probe addressed by the
datalogger will respond. All other probes will remain active until the timeout
period expires.
Example:
Probe: Water Content
Power Usage:
Quiescent: 0.25 mA
Measurement: 120 mA
Measurement time: 15 s

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR800 Series and is the answer not in the manual?

Campbell CR800 Series Specifications

General IconGeneral
BrandCampbell
ModelCR800 Series
CategoryData Loggers
LanguageEnglish

Related product manuals