Section 8.  Operation 
 
 
To copy files to these drives, choose File Control from the datalogger support 
software 
(p. 494) menu. 
 
FIGURE 96:   Preconfigured HTML Home Page 
 
 
8.10.1.6.2  Custom HTTP Web Server 
Although the default home page cannot be accessed for editing, it can be replaced 
with the HTML code of a customized web page. To replace the default home 
page, save the new home page under the name default.html and copy it to the 
datalogger. It can be copied to a CR800 drive with File Control. Deleting 
default.html will cause the CR800 to use the original, default home page. 
The CR800 can be programmed to generate HTML or XML code that can be 
viewed by a web browser.    CRBasic example HTML
 (p. 432) shows how to use the 
CRBasic instructions WebPageBegin() / WebPageEnd and HTTPOut() to 
create HTML code. Note that for HTML code requiring the use of quotation 
marks, CHR(34) is used, while regular quotation marks are used to define the 
beginning and end of alphanumeric strings inside the parentheses of the 
HTTPOut() instruction. For additional information, see the CRBasic Editor Help. 
In this example program, the default home page is replaced by using 
WebPageBegin to create a file called default.html. The new default home page 
created by the program appears as shown in the figure Home Page Created using 
WebPageBegin() Instruction 
(p. 432). 
The Campbell Scientific logo in the web page comes from a file called 
SHIELDWEB2.JPG that must be transferred from the PC to the CR800 CPU: 
drive using File Control in the datalogger support software. 
A second web page, shown in figure Customized Numeric-Monitor Web Page
 (p. 
432) 
called "monitor.html" was created by the example program that contains links 
to the CR800 data tables.