EasyManua.ls Logo

Campbell CR800 Series - Callandar-Van Dusen Coefficients for PT100, Α = 0.00385

Campbell CR800 Series
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 7. Installation
261
PT100 Temperature and ideal resistances (RS);
α =
0.00385
1
RS
40
RS
0
RS
10
RS
60
°C 40 0 10 60
84270 100000 103900 123240
1
Commonly available tables provide these resistance values.
Callandar-Van Dusen Coefficients for PT100, α = 0.00385
Constants Coefficient
a 3.9083000E-03
d -2.3100000E-06
e 1.7584810E-05
f -1.1550000E-06
g 1.7909000E+00
h -2.9236300E+00
i 9.1455000E+00
j 2.5581900E+02
Input Ranges (mV)
CR6 CR800/CR1000 CR3000
±5000 ±5000 ±5000
±1000 ±2500 ±1000
±200 ±250 ±200
±25 ±50
±7.5 ±20
±2.5
Input Limits (mV)
CR6 CR800/CR1000 CR3000
±5000 ±5000 ±5000