Appendix A. Info Tables and Settings
551
SystemProcTime
FLOAT Y
Status table field: ≈37
Time (μs) required to process auto (background) calibration. Default is a large number until
auto self-calibration runs.
Info Tables and Settings: T
Keyword Data Type
Read Only
• Where to Find
Description
TCPClient
Connections
Discontinued; replaced by / aliased to PakBusTCPClients
(p. 546).
TCPPort
Discontinued; replaced by / aliased to PakBusPort
(p. 546).
TelnetEnabled
NUMERI
C
Settings Editor: Network Services | Telnet Enabled
Enables (True) or disables (False) the Telnet service.
TimeStamp NSEC Y Scan-time that a record was generated.
Info Tables and Settings: U
Keyword Data Type
Read Only
• Where to Find
Description
UDPBroadcast
Filter
UINT2
Settings Editor: Advanced | IP Broadcast Filtered
Default = 0.
USRDriveFree
Numeric Y
Keyboard: Settings (Advanced)
Bytes remaining on the USR: drive. USR: drive is user-created and normally used to store
.jpg and other files. Default = 0.
USRDriveSize
Numeric
Settings Editor: Advanced | USR: Drive Size
Sets size (bytes) of the USR: drive. If 0 (default), the drive is removed. If non-zero, the
drive is created. A change will cause the CRBasic program to recompile.
UTCOffset
Numeric
Settings Editor: Advanced | UTC Offset
Difference (s) between local time (CR800 clock) and UTC. Used in email, HTML headers,
GPS(), NetworkTimeProtocol(), and DaylightSavingTime(). Default = -1 (disabled).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR800 Series and is the answer not in the manual?

Campbell CR800 Series Specifications

General IconGeneral
BrandCampbell
ModelCR800 Series
CategoryData Loggers
LanguageEnglish

Related product manuals