Section 8. Operation
330
measurement with input reversal at a temperature between 0 to 40
°C.
Measurement Accuracy Example
The following example illustrates the effect percent-of-reading and offset have on
measurement accuracy. The effect of offset is usually negligible on large signals:
Example:
Sensor-signal voltage: ≈2500 mV
CRBasic measurement instruction: VoltDiff()
Programmed input-voltage range (Range): mV2500 (±2500 mV)
Input measurement reversal (RevDiff): True
CR800 circuitry temperature: 10 °C
Accuracy of the measurement is calculated as follows:
accuracy = percent-of-reading + offset