CR800 Terminal Commands
Command Description Use
P
Serial talk through
Issue commands from keyboard that are passed through
the logger serial port to the connected device. Similar in
concept to SDI12 Talk Through. No timeout when
connected via PakBus.
REBOOT
Program recompile
Typing “REBOOT” rapidly will recompile the CR800
program immediately after the last letter, "T", is
entered. Table memory is retained. NOTE When
typing REBOOT, characters are not echoed (printed on
terminal screen).
SDI12
SDI12 talk through
Issue commands from keyboard that are passed through
the CR800 SDI-12 port to the connected device. Similar
in concept to Serial Talk Through.
T
Unused
U
Data recovery
Provides the means by which data lost when a new
program is loaded may be recovered. See section
Troubleshooting Data Recovery
(p. 486) for details.
V
Low level memory dump Campbell Scientific engineering tool
W
Comms Watch (Sniff)
Enables monitoring of CR800 communication traffic.
No timeout when connected via PakBus.
X
Peripheral bus module identify Campbell Scientific engineering tool
FIGURE 115: DevConfig Terminal Tab