476 Upgrade and Maintenance Manual TX2550 M4
Converting a floorstand model to a rack model
Figure 340: Securing the accessible drive cage (B)
Ê Carefully turn the server upside down.
I At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
Ê Secure the accessible drive cage with the two screws (see circles) to the
bottom side of the server.
I Note the correct screw positions: The screw hole on the right that has
been used in the floorstand configuration remains empty.
Ê Install the front panel module, see section "Installing the front panel module"
on page 410.
Ê If applicable, install all accessible drives, see section "Installing an
accessible drive" on page 379.
Ê If applicable, install an HDD extension box, see section "HDD/SSD
extension boxes" on page 241.
Preparing the intrusion switch
Ê Remove the intrusion switch module, see section "Removing the intrusion
switch cable" on page 482.
Ê Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module, see section "Installing the intrusion
switch cable" on page 485.