10.8 Port Number
193
Chapter 10 Setting Method for Logger
10
This section describes setting the port number for LAN communication. See
"LAN Connection Examples" (p. 71).
1. Turn the power on while pressing
and then release the key
when the model name and version
appear in the display area.
The instrument enters setting mode.
2. Press multiple times until the following port number setting screen
appears.
3. Press to move the flashing cursor to the position to change.
Each press of the key moves the flashing cursor to the right.
4. Press to increase the value at the flashing cursor in increments of 1.
The value cannot be decremented.
5. Press to move the flashing cursor to [SET], and press to con-
firm the setting.
6. Press multiple times until the following setting mode end screen
appears.
7. Press to end setting mode.
The logger uses the TCP/IP protocol during communication. TCP/IP allows each
communication device to establish multiple connections, so port numbers are
used to differentiate between the connections. The logger uses a pre-defined
number from 8800 to 8009. There is normally no need to change a port number,
but if there is a port that cannot be used because of a network security problem,
change the value. The first digit of the port number is reserved.
10.8 Port Number