05/2011
4.6.7 bridge address-relearn detect operation
This command enables or disables Bridge Address Relearn Detection.
The default value is disable.
Default
Disabled
Format
bridge address-relearn detect operation
{disable|enable}
Mode
Global Config
4.6.8 bridge address-relearn detect threshold
This command defines the value of relearned addresses to signal address
relearn threshold exceeded.
The default relearn threshold is 1. Possible values to configure threshold
count are 1 to 1024.
Default
1
Format
bridge address-relearn-detect threshold <value>
Mode
Global Config
value
1 to 1024