CLI Commands: Base
CLI L2P
Release
7.0
05/2011
4.6
Management Commands
101
4.6.9 bridge aging-time
This command configures the forwarding database address aging timeout in
seconds.
Default
30
Format
bridge aging-time <10-630>
Mode
Global Config
Seconds
The <seconds> parameter must be within the range of 10 to 630 sec-
onds.
U no bridge aging-time
This command sets the forwarding database address aging timeout to
30 seconds.
Format
no bridge aging-time
Mode
Global Config