CLI L2P
Release
7.0
05/2011
4.14
PTP - Precision Time Protocol
371
4.14.38ptp v2tc pdelay-interval
Configure the Peer Delay Interval in seconds {1|2|4|8|16|32}. This interval is
used if delay-mechanism is set to p2p.
Format
ptp v2tc pdelay-interval {1|2|4|8|16|32}
Mode
Interface Config
4.14.39ptp v2tc primary-domain
Configure the PTPv2 Transparent Clock (IEEE1588-2008) specific settings.
Configure the primary-domain {for syntonization} of the transparent-clock.
Format
ptp v2tc primary-domain <0-255>
Mode
Global Config
4.14.40ptp v2tc syntonization
Configure the PTPv2 Transparent Clock (IEEE1588-2008) specific settings.
Enable or disable the syntonization of the transparent-clock.
Format
ptp v2tc syntonization {enable|disable}
Mode
Global Config