4.12
LLDP - Link Layer Discovery Protocol
CLI L2P
Release
7.0
05/2011
4.12.20lldp config chassis notification-interval
Configure the LLDP minimum notification interval (the minimum time after a
notification trap has been sent until a new trap can be sent, unit: seconds,
min.: 5 sec., max.: 3600 sec., default: 5 sec.).
Format
lldp config chassis notification-interval
<notification interval>
Mode
Global Config
Notification interval
Configure the LLDP minimum notification interval (the minimum time
after a notification trap has been sent until a new trap can be sent,
unit: seconds, min.: 5 sec., max.: 3600 sec., default: 5 sec.).
4.12.21lldp config chassis re-init-delay
Configure the LLDP re-initialization delay (unit: seconds, min.: 1 sec., max.:
10 sec., default: 2 sec.).
Format
lldp config chassis re-init-delay <re-init delay>
Mode
Global Config
Re-init-delay
Configure the LLDP re-initialization delay (unit:seconds, min.: 1 sec.,
max.: 10 sec., default: 2 sec.).

Table of Contents

Other manuals for Hirschmann MACH 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1000 and is the answer not in the manual?

Hirschmann MACH 1000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1000
CategorySwitch
LanguageEnglish

Related product manuals