4.6.34 serial timeout
This command specifies the maximum connect time (in minutes) without
console activity. A value of 0 indicates that a console can be connected in-
definitely. The time range is 0 to 160.
Default
5
Format
serial timeout <0-160>
Mode
Line Config
U no serial timeout
This command sets the maximum connect time without console activity
(in minutes) back to the default value.
Format
no serial timeout
Mode
Line Config