CLI Commands: Security
CLI L2P
Release
7.0
05/2011
6.1
Security Commands
531
6.1.37 show radius statistics
This command is used to display the statistics for RADIUS or configured
server . To show the configured RADIUS server statistic, the IP Address
specified must match that of a previously configured RADIUS server. On ex-
ecution, the following fields are displayed.
Format
show radius statistics [ipaddr]
Mode
Privileged EXEC and User EXEC
If ip address is not specified than only Invalid Server Address field is dis-
played. Otherwise other listed fields are displayed.
Invalid Server Addresses
The number of RADIUS Access-Response packets received from unknown
addresses.
Server IP Address
Round Trip Time
The time interval, in hundredths of a second, between the most
recent Access-Reply | Access-Challenge and the Access-Request
that matched it from the RADIUS authentication server.
Access Requests
The number of RADIUS Access-Request packets sent to this server.
This number does not include retransmissions.
Access Retransmission
The number of RADIUS Access-Request packets retransmitted to
this RADIUS authentication server.
Access Accepts
The number of RADIUS Access-Accept packets, including both valid
and invalid packets, which were received from this server.

Table of Contents

Other manuals for Hirschmann MACH 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1000 and is the answer not in the manual?

Hirschmann MACH 1000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1000
CategorySwitch
LanguageEnglish

Related product manuals