360
4.14
PTP - Precision Time Protocol
CLI L2P
Release
7.0
05/2011
4.14.13ptp v1 sync-interval
Configure the PTPv1 (IEEE1588-2002) specific settings.
Configure the Precision Time Protocol sync interval. The sync interval is the
interval (in seconds) between successive sync messages issued by a master
clock.
Valid values are: sec-1, sec-2, sec-8, sec-16, and sec-64. Default is sec-2.
Note: changes are only applied after the 're-initialize' command or after a
reboot if the configuration was saved.
Format
ptp v1 sync-interval {sec-1|sec-2|sec-8|sec-16|
sec-64}
Mode
Global Config
sec-1
Set the PTP sync interval to sec-1 (1 sec).
sec-2
Set the PTP sync interval to sec-2 (2 sec).
sec-8
Set the PTP sync interval to sec-8 (8 sec).
sec-16
Set the PTP sync interval to sec-16 (16 sec).
sec-64
Set the PTP sync interval to sec-64 (64 sec).