4.11
System Utilities
CLI L2P
Release
7.0
05/2011
<seconds>
The number of seconds after which the switch will reboot.
Value range: None (no reboot sceduled), 0 - 2,147,483 sec (= 596 h +
31 min + 23 sec) .
4.11.29reload
This command enables you to reset the switch (warm start) after a given time
delay, for cold start See “reboot” on page 301.
Note: First, the device is checking the software in the flash memory and then
it resets. If a warm start is not possible, the device automatically executes a
cold start.
Reset means that all network connections are terminated and the boot code
executes. The switch uses the stored configuration to initialize the switch.
You are prompted to confirm that the reset should proceed. A successful
reset is indicated by the LEDs on the switch.
Format
reload {delay <seconds>}
Mode
Privileged EXEC
<seconds>
The number of seconds after which the switch will reload.
Value range: 0 - 2,147,483 sec.
U clear reload
This command cancels a scheduled reload.

Table of Contents

Other manuals for Hirschmann MACH 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1000 and is the answer not in the manual?

Hirschmann MACH 1000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1000
CategorySwitch
LanguageEnglish

Related product manuals