EasyManuals Logo

Hirschmann MACH 1000 Reference Manual

Hirschmann MACH 1000
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #215 background imageLoading...
Page #215 background image
CLI L2P
Release
7.0
05/2011
4.9
Device Configuration Commands
215
4.9.57 show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) in-
formation for one or all interfaces.
Format
show gmrp configuration {<slot/port> | all}
Mode
Privileged EXEC and User EXEC
Interface
This displays the slot/port of the interface that this row in the table
describes.
Join Timer
Specifies the interval between the transmission of GARP PDUs regis-
tering (or re-registering) membership for an attribute. Current attri-
butes are a VLAN or multicast group. There is an instance of this
timer on a per-Port, per-GARP participant basis. Permissible values
are 10 to 100 centiseconds (0.1 to 1.0 seconds). The factory default is
20 centiseconds (0.2 seconds). The finest granularity of specification
is 1 centisecond (0.01 seconds).
Leave Timer
Specifies the period of time to wait after receiving an unregister
request for an attribute before deleting the attribute. Current attributes
are a VLAN or multicast group. This may be considered a buffer time
for another station to assert registration for the same attribute in order
to maintain uninterrupted service. There is an instance of this timer on
a per-Port, per-GARP participant basis. Permissible values are 20 to
600 centiseconds (0.2 to 6.0 seconds). The factory default is 60 centi-
seconds (0.6 seconds). The finest granularity of specification is 1 cen-
tisecond (0.01 seconds).
LeaveAll Timer
This Leave All Time controls how frequently LeaveAll PDUs are gen-
erated. A LeaveAll PDU indicates that all registrations will shortly be
deregistered. Participants will need to rejoin in order to maintain reg-
istration. There is an instance of this timer on a per-Port, per-GARP
participant basis. The Leave All Period Timer is set to a random value
in the range of LeaveAllTime to 1.5*LeaveAllTime. Permissible values
are 200 to 6000 centiseconds (2 to 60 seconds). The factory default is

Table of Contents

Other manuals for Hirschmann MACH 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1000 and is the answer not in the manual?

Hirschmann MACH 1000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1000
CategorySwitch
LanguageEnglish

Related product manuals