CLI L2P
Release
7.0
05/2011
4.9
Device Configuration Commands
215
4.9.57 show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) in-
formation for one or all interfaces.
Format
show gmrp configuration {<slot/port> | all}
Mode
Privileged EXEC and User EXEC
Interface
This displays the slot/port of the interface that this row in the table
describes.
Join Timer
Specifies the interval between the transmission of GARP PDUs regis-
tering (or re-registering) membership for an attribute. Current attri-
butes are a VLAN or multicast group. There is an instance of this
timer on a per-Port, per-GARP participant basis. Permissible values
are 10 to 100 centiseconds (0.1 to 1.0 seconds). The factory default is
20 centiseconds (0.2 seconds). The finest granularity of specification
is 1 centisecond (0.01 seconds).
Leave Timer
Specifies the period of time to wait after receiving an unregister
request for an attribute before deleting the attribute. Current attributes
are a VLAN or multicast group. This may be considered a buffer time
for another station to assert registration for the same attribute in order
to maintain uninterrupted service. There is an instance of this timer on
a per-Port, per-GARP participant basis. Permissible values are 20 to
600 centiseconds (0.2 to 6.0 seconds). The factory default is 60 centi-
seconds (0.6 seconds). The finest granularity of specification is 1 cen-
tisecond (0.01 seconds).
LeaveAll Timer
This Leave All Time controls how frequently LeaveAll PDUs are gen-
erated. A LeaveAll PDU indicates that all registrations will shortly be
deregistered. Participants will need to rejoin in order to maintain reg-
istration. There is an instance of this timer on a per-Port, per-GARP
participant basis. The Leave All Period Timer is set to a random value
in the range of LeaveAllTime to 1.5*LeaveAllTime. Permissible values
are 200 to 6000 centiseconds (2 to 60 seconds). The factory default is

Table of Contents