CLI Commands: Base
CLI L2P
Release
7.0
05/2011
4.6
Management Commands
137
readwrite
Enable SNMP read-write access to this switch (enable write access)
by SNMPv3 protocol version.
4.6.50 snmp-server
This command sets the name and the physical location of the switch, and the
organization responsible for the network.The range for name, location and
contact is from 0 to 64 alphanumeric characters.
Default
None
Format
snmp-server
{community <name> |
ipaddr <ipaddr> <name> |
ipmask <ipmask> <name> |
mode <name> |
ro <name> |
rw <name> |
contact <con> |
enable traps { chassis | l2redundancy |
linkmode | multiusers | port-sec | stpmode }
location <loc> |
sysname <name> }
Mode
Global Config