4.9.32 set garp timer leaveall
This command sets how frequently Leave All PDUs are generated per port. A
Leave All PDU indicates that all registrations will be unregistered. Participants
would need to rejoin in order to maintain registration. The value applies per
port and per GARP participation. The time may range from 200 to 6000 (cen-
tiseconds). The value 1000 centiseconds is 10 seconds.
Note: This command has an effect only when GVRP is enabled.
Default
1000
Format
set garp timer leaveall <200-6000>
Mode
Global Config
Interface Config
U no set garp timer leaveall
This command sets how frequently Leave All PDUs are generated per
port to 1000 centiseconds (10 seconds).
Note: This command has an effect only when GVRP is enabled.
Format
no set garp timer leaveall
Mode
Global Config
Interface Config