CLI Commands: Base
CLI L2P
Release
7.0
05/2011
4.1
System Information and Statistics Com-
55
4.1.12 show device-status
The signal device status is for displaying
D the monitoring functions of the switch,
D the device status trap setting.
Format
show device-status
[monitor|state|trap]
Mode
Privileged EXEC and User EXEC
Device status monitor
Displays the possible monitored events and which of them are
monitored:
– the detected failure of at least one of the supply voltages.
– the removal of the ACA
– the removal of a media module
– the temperature limits
– the defective link status of at least one port. With the switch, the
indication of link status can be masked by the management for each
port. Link status is not monitored in the delivery condition.
– the loss of Redundancy guarantee.
Ring/network coupling:
– The following conditions are reported in Stand-by mode:
– interrupted control line
– partner device running in Stand-by mode.
HIPER-Ring:
– The following condition is reported in RM mode additionally:
– Ring redundancy guaranteed. Ring redundancy is not monitored in
the delivery condition.
Device status state
Error The current device status is error.
No Error The current device status is no error.
Device status trap
enabled A trap is sent if the device status changes.
disabled No trap is sent if the device status changes.

Table of Contents

Other manuals for Hirschmann MACH 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1000 and is the answer not in the manual?

Hirschmann MACH 1000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1000
CategorySwitch
LanguageEnglish

Related product manuals