CLI Commands: Switching
414
5.1
Spanning Tree Commands
CLI L2P
Release
7.0
05/2011
5.1.16 spanning-tree forward-time
This command sets the Bridge Forward Delay parameter to a new value for
the common and internal spanning tree. The forward-time value is in seconds
within a range of 4 to 30, with the value being greater than or equal to
"(Bridge Max Age / 2) + 1".
Default
15
Format
spanning-tree forward-time <4-30>
Mode
Global Config
U no spanning-tree forward-time
This command sets the Bridge Forward Delay parameter for the common
and internal spanning tree to the default value, i.e. 15.
Format
no spanning-tree forward-time
Mode
Global Config