4.11
System Utilities
CLI L2P
Release
7.0
05/2011
4.11.20device-status connection-error
This command configures the device status link error monitoring for this port.
Default
ignore
Format
device-status connection-error {ignore|propagate}
Mode
Interface Config
4.11.21device-status monitor
This command configures the device-status.
Format
device-status monitor
{aca-removal | all | connection-error |
hiper-ring |
module-removal | power-supply-1 |
power-supply-2 | power-supply-3-1 |
power-supply-3-2 |power-supply-4-1 |
power-supply-4-2 | ring-coupling | temperature }
{error|ignore}
device-status trap {disable|enable}
Mode
Global Config
monitor
Determines the monitoring of the selected event or all events.
– error If the given event signals an error, the device state will also
signal error,
– ignore Ignore the given event - even if it signals an error, the
device state will not signal 'error' because of that.