CLI L2P
Release
7.0
05/2011
4.14
PTP - Precision Time Protocol
365
4.14.23ptp v2bc operation
Enable or disable the sending and receiving / processing of PTP synchroni-
zation messages.
Format
ptp v2bc operation {disable|enable}
Mode
Interface Config
enable
Port sends and receives/ processes PTP synchronization messages.
disable
Port blocks PTP synchronization messages.
4.14.24ptp v2bc announce-interval
Configure the Announce Interval in seconds {1|2|4|8|16}.
Format
ptp v2bc announce-interval {1|2|4|8|16}
Mode
Interface Config