4.9.49 set igmp querier max-response-time
Configure the IGMP Snooping Querier's maximum response time. The range
is 1 to 3,598 seconds. The default value is 10 seconds.
Default
10
Format
set igmp querier max-response-time <1-3598>
Mode
Global Config
Note: The IGMP Snooping max. response time was also set. It is always the
same value as the IGMP Querier´s max. response time.
4.9.50 set igmp querier protocol-version
Configure the IGMP Snooping Querier's protocol version (1, 2 or 3).
Default
2
Format
set igmp querier protocol-version {1 | 2 | 3}
Mode
Global Config