4.9
Device Configuration Commands
CLI L2P
Release
7.0
05/2011
4.9.44 set igmp groupmembershipinterval
This command sets the IGMP Group Membership Interval time on the sys-
tem. The Group Membership Interval time is the amount of time in seconds
that a switch will wait for a report from a particular group on a particular inter-
face before deleting the interface from the entry. This value must be greater
than the IGMP Maximum Response time value. The range is 3 to
3,600 seconds.
Default
260
Format
set igmp groupmembershipinterval <3-3600>
Mode
Global Config
U no set igmp groupmembershipinterval
This command sets the IGMP Group Membership Interval time on the
system to 260 seconds.
Format
no set igmp groupmembershipinterval
Mode
Global Config