Command Manual - Integrated Management
Quidway S2000 Series Ethernet Switches Chapter 1 HGMP V2 Configuration Commands
1-8
Timer : 0 min
Hop Delay : 200 ms
Port Delay: 20 ms
Last collection total time: 2216ms
Table 1-2 Description of global NTDP configuration information
Field Description
NTDP is running. The global NTDP is enabled on the local device.
Hops Hops for topology collection.
Timer Interval of periodic topology collection.
Hop Delay Delay that the device forwards topology collection request.
Port Delay Delay that the port forwards topology collection request.
Last collection total time Time taken by last collection.
1.2.2 display ntdp device-list
Syntax
display ntdp device-list [ verbose ]
View
All view
Parameter
verbose: Display the detailed information about the device.
Description
Using display ntdp device-list command, you can view the device information
collected through NTDP.
Example
# Display the device list collected through NTDP.
<Quidway> display ntdp device-list
MAC HOP IP PLATFORM
00e0-fc10-0000 1 Quidway S3526
00e0-fc07-3c00 3 Quidway S3526
00e0-fc07-4de0 2 192.169.121.257/25 Quidway S3526
00e0-fc07-0bc0 0 Quidway S3526

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S2000 Series and is the answer not in the manual?

Huawei Quidway S2000 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S2000 Series
CategorySwitch
LanguageEnglish

Related product manuals