Command Manual - System Management
Quidway S2000 Series Ethernet Switches Chapter 6 RMON Configuration Commands
6-6
Sampling interval : 10(sec)
Rising threshold : 1000(linked with event 1)
Falling threshold : 100(linked with event 1)
When startup enables : risingOrFallingAlarm
This entry will exist : forever.
Latest value : 0
Table 6-5 Output description of the display rmon prialarm command
Field Description
Prialarm table 1 Index of extended alarm entry.
owned by HUAWEI Creator of the extended alarm entry.
VALID The entry corresponding to the index is valid.
Samples absolute value
Sampling the absolute value of the node
1.3.6.1.2.1.16.1.1.1.4.1
Rising threshold
Rising threshold. When sampling value rises from normal
value to this threshold, rising threshold alarm will be triggered.
Falling threshold
Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm will be
triggered.
linked with event 1 Corresponding event index of ring and falling threshold alarm.
When startup enables: risingOrFallingAlarm
Kind of first alarm. It may trigger rising threshold alarm or
falling threshold alarm or both.
This entry will exist forever
The lifespan of this alarm entry which can be forever or a
specified period of time.
Latest value : 0 The value of the latest sampling.
6.1.6 display rmon statistics
Syntax
display rmon statistics [
port-num
]
View
Any view
Parameter
port-num
: Ethernet port number.
Description
Using display rmon statistics command, you can view RMON statistics.
The displayed information includes collision, CRC (Cyclic Redundancy Check) and
queue, undersized or oversized packet, timeout, fragment, broadcast, multicast,
unicast, and bandwidth utility.